Testing a FIRE DOOR as a complete assembly
is the only way to prove that it is going to
fulfill its rating and defined purpose. That is
the basis of certification.
GMP Doors are currently tested to BS 476 part
22 or EN1634, which require the test to be
undertaken as a complete assembly including
door leaf, frame, ironmongery and glazing.
A rating is than given to the door assembly
based on the time it has held back the fire
without being breached.
GMP has achieved a 120 min fire rating of its
integrity (test no. 167954) of its doors under
the stringent tests held by Warrington fire
global safety.
FIRE DOORSET SPECIFICATION
DOOR LEAF :
:
(GPSP) ASTM A 527/ ASTM A525, JIS G 3302 or BS 2989 (1194). Zinc Coating
120-180g/m2. Lock formed, 4mm thick hinge, reinforcing plates, hardware
mounting plates and lock reinforcement.
DOOR FRAME :
:
GPSP sheet with welded or knockdown constructions with 4mm hinge
reinforcing plates, fixing straps, hardware mounting plates and mortar guards.